Oblasti primjene

A1 vatrootpornost



Primjena

KS1000 FH fasadni i zidni paneli ispune kamenom vunom koriste skriveni spoj pričvršćivanja i mogu biti postavljeni vertikalno ili horizontalno, a pogodni su kao zidne obloge na svim tipovima objekata, osim na onim gdje je unutarnja temperatura manja od 0 °C.

Dužine panela

Standardne dužine panela su od 2000 mm do 14500 mm.
Za panele kraće od 2000 mm i duže od 14500 mm molimo kontaktirajte: Kingspan odjeljenje tehničkih usluga.




Sendvič paneli, Zidni paneli KS1000 FHSendvič paneli, Zidni paneli KS1000 FH


Izbor karakteristika proizvoda

External Facing Profiles

Sendvič paneli, Zidni paneli KS1000 FH
Sendvič paneli, Zidni paneli KS1000 FH


Internal Facing Profiles

Sendvič paneli, Zidni paneli KS1000 FH

Debljina ispune (mm) 80 100 120 150
k vrijednost (W/m²K) 0.46 0.37 0.32 0.26
Težina (kg/m2) obloga 0.6/0.5 mm 20.20 22.80 25.40 29.30

Materials

MATERIALS - STEEL

Galvanic protection options

  1. Hot-dip zinc coated steel with a total of 275g/m2 of zinc, according to EN 10147:2000. This can be finished with a number of coating - polyester, PVDF, Plastisol and Foodsafe finishes.
  2. Galvatite coated steel in accordance with EN 10147, for Celestia finishes.
  3. Galvalloy (hot-dip coated with eutectic alloy of approx. 95% Zn, 5% Al and other elements) in accordance with EN 10214 for coated steel HPS200.

Substrate thicknesses

  • Standard external sheet thickness 0.50 mm.
  • Standard internal sheet thickness 0.40 mm.
  • Other thicknesses are available by arrangement with Kingspan.

External Coating Options

1. Standard Polyester – PES

Polyester is a universal, economic coating system suitable for exterior and interior applications. The nominal coating thickness is 25 µm.

2. PVDF

PVDF offers unequalled colour and gloss retention and good corrosion resistance. The nominal coating thickness is 25 µm. It can be used in climates with extremely high UV radiation combined with extreme temperatures and relative humidity. The standard colour range includes metallic silver.

3. HPS200 (by Corus)

HPS200 is a premium architectural coating system, tested in the laboratory and on site in severe climates, for use worldwide. Its tough, 200 µm (nominal thickness) coating has the unique Scintilla finish and is available in bright or subtle hues, providing architects with an extensive palette of colours.

4. Plastisol 200 µm

Plastisol is a high performance coating system with a grain finish and a nominal thickness of 200 µm. Typical properties of Plastisol are excellent abrasion, high corrosion resistance, excellent flexibility and therefore very good scratch resistance.

5. Celestia (by Corus)

Celestia is a metallic-finish cladding steel with a 120 µm (nominal thickness) high performance Plastisol coating. The standard product has a high performance polyester coating on the reverse side. The metallic finish captures light and movement, giving depth and life to the cladding surfaces.

Internal Coating Options

1. Polyester

Polyester coating with a nominal thickness of 15 µm. The standard colour is grey white, (similar RAL 9002).

2. Lining enamel

Lining enamel with a nominal thickness of 22 µm with a white finish.

3. Foodsafe

The surface of this 150 µm thick polymer coating is non-toxic and resistant to mould, durable and easy to clean. It is chemically inert and safe for continuous contact with unpacked food. The standard colour is white. Consult Kingspan about the availability of other colours.
Other coating systems are available by discussion with Kingspan.


INSULATION CORE

Mineral fiber of a high density (> 100 kg/m3) suitable for use in application, where higher fire resistance is required.


 

 

 

MATERIALS - ALUMINIUM

Plain and coloured aluminium is available on a project specific basis. Contact Kingspan Technical Services.

 

 

Seals and Fillers

End Lap

All end laps(cill,windows,doors) to be sealed along full width using PEself-adhesive sealant tape- 10x4 (10x3) site applied (see construction details)


Junctions

Junctions between the roof panel system / wall panel system and all gaps filled with MW fibre. Internal face of panel to be air sealed along the full length by PE self- adhesive sealant tape 9 x 3 mm. Self-adhesive sealant tape PE 20x5mm to be continously applied between panel and steel support only at locations where the internal junction reguires sealing.


Perfomance

Thermal Insulation

Panel Thickness

U value (W/m2K)

(mm)

HCFC Free = 0.022

80

0.50

100

0.41

120

0.34

150

0.28


Biological

Kingspan insulated sandwich panels are immune to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are non-deleterious.

Fire

KS1000 FH insulated sandwich panels have been tested and approved and comply with National Building Regulations and standards.

Panel Thickness (mm) Fire rating
80  
100  
120  
150  

Acoustics

Measurement of the sound insulation index of panel KS1000 FH is being prepared.

Packing and Delivery

Packing

Standard packing – road transportation

KS1000 FH panels are stacked weather side to internal side. The top, bottom, sides and ends are protected with foam and timber packing and the entire palette is wrapped in plastic.
The number of panels in each pack depends on panel thickness and length. The table below is shown as a guide. Quantities are reduced for exceptionally long panels. Typical palette height is 1,100 mm.
Maximum palette weight is 1,500 kg.

Panel core thickness (mm) 80 100 120 150
Number of panels in package 13 10 8 7


Delivery

All deliveries (unless indicated otherwise) are by road transport to project site. Off loading is the responsibility of the client.

 

Structural Tables

Sendvič paneli, Zidni paneli KS1000 FH

Sendvič paneli, Zidni paneli KS1000 FH

Site Instalation
Quality/Waranties

QUALITY & WARANTIES

Quality

Kingspan insulated sandwich panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with ISO9001:2000 standards, ensuring long term reliability and service life.

Building Regulations

Kingspan KS1000 FH insulated sandwich panels conform to the National Building Regulations and standards.

Guarantees & Warranties

Kingspan will provide external coating and product guarantees on a project by project basis.

Certification Reference

Fastener Selector

Fastener Selection – SFS intec

Product: STEEL – KS1000 FH Wall System, Fixing position: VALLEY (22 mm diameter sealing washer)

Sendvič paneli, Zidni paneli KS1000 FH
Sendvič paneli, Zidni paneli KS1000 FH


Product: CONCRETE – KS1000 FH Wall System, Fixing position: VALLEY (22 mm diameter sealing washer)

Sendvič paneli, Zidni paneli KS1000 FH


Product: TIMBER – KS1000 FH Wall System, Fixing position: VALLEY (22 mm diameter sealing washer)

Sendvič paneli, Zidni paneli KS1000 FH



Fastener Selection – EJOT

Product: STEEL – KS1000 FH Wall System, Fixing position: VALLEY (22 mm diameter sealing washer)

Sendvič paneli, Zidni paneli KS1000 FH
Sendvič paneli, Zidni paneli KS1000 FH


Product: CONCRETE – KS1000 FH Wall System, Fixing position: VALLEY (22 mm diameter sealing washer)

Sendvič paneli, Zidni paneli KS1000 FH




Product: TIMBER – KS1000 FH Wall System, Fixing position: VALLEY (22 mm diameter sealing washer)

Sendvič paneli, Zidni paneli KS1000 FH


 

Standard Details

Side Lap Detail
Construction Method
Gable Detail
Mono Ridge Detail
Gable Wall Parapet Detail
Eaves Detail
Panel to Panel Junction
Roof to Wall Junction
Expansion Joint
Corner Detail
Concrete Wall Cill
Plastic Window – Head
Plastic Window
Aluminium Window – Head
Aluminium Window – Cill
Aluminium Window – Jamb
Aluminium Window
Plastic Door
Roller Shutter Door
Wall Junction
Louvre
Window Layouts

Gallery/case studies


How new insulated panel technology is changing the face of building design

New developments in insulation core technology mean that insulated panel systems now significantly exceeds older, ‘built-up’ construction methods for architects looking to create without compromise. Insulated panels offer almost unlimited different design combinations, while also delivering the thermal performance, long-term guarantees, speed and ease of build and environmental credentials that architects, and their customers, are looking for.

All of these benefits have driven increased demand from architects for insulated panels.

Design flexibility

Perhaps the biggest factor driving increased architectural use of insulated panel technology has been the availability of new design options. New finishes, colours, orientations and profiles mean that architects now have millions of different combinations available to the them to achieve the finish they want. When combined with the enhanced performance of panel technology, detailed below, this means that architects no longer have to sacrifice their design freedom to achieve superior building functionality.